Input Voltage: 9 to 16 VDC (Nominal: 12 VDC)
-
Current Drain: About 30 mA @ 12 VDC
-
Detector: Low noise dual-element pyroelectric sensor
-
Trip Indication: Green LED flashes for up to 5 seconds
-
True Motion Event Verification Counter: 1 or 2 events
-
Detection Pattern: A virtually conical pattern of maximum 10.8 m (35 ft) diameter, when installed on a 4.5 m (15 ft) ceiling
-
Oscillator: Microstrip DRO-stabilized type
-
Frequency: 2.45 GHz
-
Detection Range: Adjustable from 25% to 100%
-
Trip Indication: Green LED lights for up to 5 seconds
-
Alarm Indication: Red LED lights for 2-3 s (both detectors trip)
-
Relay Contacts: Normally closed, 0.1 A resistive/30 VDC; 47 Ù resistor in series with contacts
-
Alarm Duration: 2-3 seconds (red LED lights and output relay contacts open)
-
Tamper Contacts: Normally closed, 50 mA resistive/ 30 VDC
-
Trouble Output: Open-collector, 100 mA max. serial resistor 47 Ù, pull-up resistor 47 KÙ (see Fig. 4)
-
Maximum Mounting Height: 4.5 m (15 ft)
-
Dimensions (H x Ø): 24 x 86 mm (3.4 x 0.95 in.)
-
Weight: 64 g (2 oz)
-
Color: White
-
Operating Temperature: -10°C to 50°C (14°F to 122°F)
-
RFI Protection: Greater than 20 V/m (20 to 1000 MHz)(Not UL investigated)
-
U.S. Patents 5,237,330 and 5,693,943 (other patents pending)
-
Compliance with standards: EN 50131-1 Grade 2 Class II, UL-639
|