KeypadLinc Specifications
|
General |
Brand: |
Smarthome |
Manufacturer Product No.: |
2486D, INSTEON KeypadLinc Dimmer |
Warranty: |
2 years, limited |
Patent No.: |
U.S. Patent No. 7,345,998, International patents pending |
Operation |
On-Levels: |
32 locally, 1% increments with software |
Ramp Rates, (full-ON to full-OFF): |
0.125 to 9 seconds if programmed locally, 0.125 seconds to 8 minutes if programmed remotely |
LED: |
Single LED at bottom of unit, indicates supplied power and signals programming cues |
Manual Operation Modes: |
INSTEON only, X10 only, INSTEON and X10 Combo Mode |
Combo Mode Message Order: |
INSTEON, INSTEON cleanup, X10 |
Multi-Way Circuit Support: |
One KeypadLinc Dimmer controls load, Cross-Link any number of KeypadLinc Dimmers or other INSTEON Controllers |
Setup Memory: |
Non-volatile EEPROM |
INSTEON Features |
INSTEON Addresses: |
1 hard-coded out of 16,777,216 possible |
INSTEON Links: |
417 |
INSTEON Powerline Frequency: |
131.65 KHz |
INSTEON Minimum Transmit Level: |
3.2 Vpp into 5 Ohms |
INSTEON Minimum Receive Level: |
10 mV |
INSTEON Messages Repeated: |
Yes |
Mechanical |
Button Type: |
6 mechanical momentary contact type buttons |
Button Appearance: |
Solid white pre-printed plastic caps, with LED backlighting |
Wire Nuts: |
3 included |
Mounting: |
Mounts in single or multiple-ganged junction box.Controls 200 watts less load for each immediately adjacent electronic dimmer installed. For example, 600 watt load capacity becomes 400 watt with another electronic dimmer installed to the immediate right or left. Use a triple-gang box with a mechanical switch in the center to avoid de-rating |
Operating Temperature Range: |
Indoors, 32 to 104°F |
Operating Humidity Range: |
0% - 85% relative humidity |
Dimensions: |
4.1" H x 1.8" W x 1.2" D |
Weight: |
3.6 oz |
Electrical |
Supply Voltage: |
120 Volts AC +/- 10%, 60 Hertz, single phase |
Surge Protection: |
MOV rated for 150 Volts |
Power Wire Leads: |
6", 16 AWG, stranded, 600V, 105°C insulation, ends stripped and tinned, LINE (black), LOAD (red), NEUTRAL (white) |
Ground Lead: |
6", 18 AWG, stranded, bare copper |
Load Types: |
Wired-in incandescent lighting devices |
Neutral Wire |
Required |
Maximum Amps |
5-amps |
Maximum Load: |
600 Watts (uses 12-Amp triac dimmer) |
Certification: |
Safety tested for use in USA and Canada (ETL #3059287-001) |
X10 Features |
X10 Primary Address: |
1 optional (comes unassigned) |
X10 Scene Addresses: |
255 possible |
X10 Controllable Addresses |
5 X10 address (one per button sent when pressed) |
X10 Status Response: |
Supported |
X10 Resume Dim: |
Supported (by setting Local On-Level to zero) |
X10 Powerline Frequency: |
121 KHz |
X10 Minimum Transmit Level: |
3.2 Vpp into 5 Ohms |
X10 Minimum Receive Level: |
20 mVpp nominal |
X10 Messages Repeated: |
No |